Molecular devices 384 well plate reader. x. Molecular devices 384 well plate reader

 
 xMolecular devices 384 well plate reader  Here, we show that Molecular Devices microplate readers can easily and noninvasively measure fluorescent proteins in living cells

Microplate Spectrophotometer. #3-000-510)Page 154: Ordering Parts And Accessories. For nearly 30 years, Molecular Devices has provided scientists with . Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. The washer is engineered to be simple to maintain and use, including features that reduce clogging and noise. In addition, SoftMax Pro SoftwareThe Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. The SpectraMax Paradigm Platform was able to quantify the protein down to the low picomolar level using an AlphaLISA method (Figure 1). For a higher . We would like to show you a description here but the site won’t allow us. White plates reflect the light, enabling even low levels of Luminescence to be detected. 과 같은 Parameter를 검사하여 평가할 수 있습니다. Artel MVS Bundle DM Std/800TSNB Reader Details. 0 mP 384–1. –Min. Pfa1 and Pfa1 Gpx4-KO cells stably overexpressing murine FSP1 were seeded on separate 384-well plates (500 cells per well), and screened with a library of small-molecule inhibitor compounds, as. : 2 Oct 12 Page 1 of 20 Setup Guide on the Molecular Devices SpectraMax® Paradigm® Microplate Detection Platform Have a question? Contact our Technical Support Team NA: 800-955-6288 or INTL: 760-603-7200 ext. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. Here, we demonstrate that with Molecular Devices SpectraMax® microplate readers and the Quant-iT PicoGreen assay, users can reliably measure concentrations as low as 50 pg/mL of double-stranded DNA. 2. For more sample throughput, the system canPlate Background OD, which was used for subsequent tests, was measured as follows. Includes PC and software. #PLUS 384) UV-transparent 96-well microplates (Corning cat. Page 1 SpectraMax M2/M2 user guide ® A MULTI-DETECTION MICROPLATE READER WITH TWO-MODE CUVETTE PORT. x. Before you do a bottom read, or use high profile (6-well, 12-well, 24-well, or 48-well) plates, you must remove the plate adapter from the plate drawer. SpectraMax M2 and M2e Microplate Reader User Guide Plate Adapter Before you read standard 96-well or 384-well plates from the top, you must insert the plate adapter in the plate drawer. • The FlexStation™ II³⁸⁴ instrument is designed for 96- and 384-well microplates. Can read 96 well plates (optional 384 well). of samples in both 96- and 384-well microplates or in a cuvette at a selected wavelength for a single point in time (endpoint), over a specified period of time (kinetic), or over a selected wavelength range (spectral scan. 25mm: Plate width: 85. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. ZERO BIAS - scores, article reviews, protocol conditions and more. Documentation:Molecular Devices microplate readers. The calculated LOQ values were 0. With optimized reagents, option to operate the. Turn on Plate Reader and wait for it to complete its start-up routine. Documentation Computer Integration Each Molecular Devices microplate reader is shipped with a license key for the SoftMax® Pro Data Acquisition and Analysis Software that you install on the computer that you use to operate the instrument. measurements in compatible Molecular Devices® microplate readers. using the upper dropdown menu to choose plate format (96 or 384 wells) and the "Select Specific" menu to choose the specific plate type. This integrated system provides users with a multi-detection for the SpectraMax Multi-Mode Microplate Reader, as well as all other Molecular Devices' microplate readers. Instruments with a 96- or 384-well format will accommodate the most commonly used plates. Figure 1. Reads 96-well microplates in 5 seconds; Reads 384-well microplates in 16 seconds, Monochromator, tunable 1. x. 130009WThe SpectraMax Paradigm reader with HTRF Detection Cartridge offers high-throughput screening capability with excellent read times and Z’ factors. 0 and dispense 10 μL to all wells of the 384-well plate(s) (see Note 13). 96 Well Plate Reader found in: Well Plate Reader Accessory, SmartReader™ 96 Microplate Absorbance Reader, SmartReader UV-Vis Microplate Reader, Stratus. Scan every well . The SpectraTest validation. The SpectraMax iD3 reader is built on the same foundation that has made our entire SpectraMax microplate reader product line among the most trusted in the. The small-footprint Multiwash+ Microplate Washer quickly washes with both 96 and 384-well plates, has 20 standard wash protocols, and a simple LCD screen interface to customize speed, volume, soak time, and aspiration settings. -Flex3 link -we don't have this) complements the Tecans, in that it has an internal 8- or 16-tip pipetting head and performs multi-label measurements [fluorescence, fluorescence resonance energy transfer (FRET) and chemiluminescence] in real-time in 96 or 384 well format. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. The results above revealed excellent detection limits and dynamic range in all three Molecular Devices microplate luminometers. 20 attomol ATP per well. MultiWash+ Microplate Washer. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. The microplate was then placed in a SpectraMax. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. SLS & DLS: 2 µL quartz cuvettes 45 µL quartz cuvettes 4 mL generic glass cuvette DLS only:Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. You should ensure that there is enough volume in compound plate wells to operate the IonWorks® system taking into account the dead volume. Algorithms are optimized for accurate cell detection and. When reading at wavelengths below 340 nm, special UV-transparent, disposable or quartz microplates andCompany Molecular Devices, LLC; Price Get Quote; Catalog Number CSI / CSI FL; Type Cell Imaging System; Measuring Time White light - 96-well/ 384 well microplate: <2 min Fluorescence - 96-well/ 384 well microplate: <8 min; Plate Formats 6, 12, 24, 96 & 384-well SBS microplates; Applications Cell Line Development, Fluorescence, Time-LapseNext-generation luminescence plate reader. x. FlexStation® 3 Multi-Mode MicroplateAlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. The LMax plate reader has similar calculations and its RLUs are comparable to those of LMax II 384. ©2017 Molecular Devices, LLC . " SpectraMax M5 micro plate reader is a multi mode plate reader (FLU, LUMN . SpectraMax i3x. 96-well (8 by 12 matrix) with a typical reaction volume between 100 and 200 µL per well. Filter 320/100 (available from Molecular Devices) Filter 616/10 (Molecular Devices cat. Typically, the full spectrum of signal from. 5 mP 1536–2. 030 fmol Fluorescence Polarization (FP). 314 low lamp level warning. Only Molecular Devices microplate plate readers offer the capability to measure the depth (optical pathlength) of samples with no temperature dependency using the patented PathCheck® Sensor technology. What is the minimum well volume needed to run a 384 well plate? Minimum volume depends on the solution (curved vs. Spectranet customer portalThe microplate reader has been around for more than three decades and continues to serve as a must-have workhorse of clinical, academic research and industrial laboratories alike. 340 PC384. flat meniscus), but is approx 15 mL. x. SpectraMax Paradigm Microplate Reader General specifications User-upgradeable Multi-Mode Detection Platform Technical specifications Optimized Guaranteed* Fluorescence Intensity (FI) (Fluorescein) 96-well (200 µL) 0. Time-resolved phosphorescence. For the 96-well plate, this equates to 1 fg per well to 1 ng per well; for the 384-well plate it is 0. 2, prime the machine with CellTiter-Glo ® 2. luminescence for a 96-well plate and 40 msec integration time for a 384-well plate: 0517 Lit. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. They perform rapid throughput cell-based assays while. x. The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Browse for different fluorescent readers below and compare across different instrument suppliers. 384 only) Selects either 96-well or 384-well plate for a stand-alone read. Molecular Devices makes. Or scan up to 384 wells at any time to determine the best assay conditions. x. SpectraMax ID5 Plate Reader (Molecular Devices). For fluorescence intensity assays, users can select from top- or bottom-read modes for improved sensitivity in solution and cell-based assays. 2. Application Area: Multi mode plate reader. Figure 2-23: Bottle holder To install the bottle holder: 1. 0112-0126B 8 Chapter1:Introduction TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate. 1: The SPECTRAmax 340PC 384 System The on-board microprocessor calculates and reports the absorbance (or % Transmittance) for each well of a microplate. #6590-0121) SpectraMax i3x® Multi-Mode Microplate Reader (Molecular Devices cat. x. Plate formats. Also refer to this Multimode Reader Comparison. Round well design with a solid black flat bottom2. where I 0 is the intensity of the incident light, and I is intensity of that light after it passed through the sample. Dimensions: 18. The StakMax® Microplate Handling System is a powerful, compact, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers for improved process flow and higher throughput. 5–25 µl. Download PDF. x. Made from polypropylene with conical well profiles to maximize recovery and allow working with sample volumes as low as 5 µL. Automated live cell imaging – cell counting and confluence. REF - For the SpectraMax Plus 384, press to do a Cuvette Reference correction method read of buffer, water, or air taken in the cuvette that is used as I to calculate Absorbance or % Transmittance with the PathCheck Pathlength Measurement Technology. Next generation SpectraMax® absorbance microplate readers. 306 plate air cal. Afterwards, 25 μL SpectraMax Glo Steady-Luc working solution was added to the wells. SpectraMax ABS Plus Microplate Reader (Molecular Devices cat. 100 µL (96-well assay) or 25 µL (384-well assay) of CellTiter-Glo reagent was added to each well. Unparalleled performance on a personalized platform. With optimized reagents, option to operate the. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. luminescence for a 96-well plate and 40 msec integration time for a 384-well plate. The fluid surface in a 384-well is a deeply curved meniscus. plated at 50,000 cells/well in 100 µL of DMEM/FBS in a 96-well plate and incubated at 37°C for five hours. Contact Us Phone: +1-800-635-5577 Web: Email: info@moldev. Products : ClonePix 2 System, QPix 450/460 Systems, QPix 420 System, CloneSelect Imager. Add the new plate. 039. …200, the Bio-Tek µQuant™, the Bio-Rad UltraMark™, the Molecular Devices SPECTRAmax® 190 and 250 plate readers. , a leading provider of high-performance life science solutions and a company of Danaher Corporation (NYSE:DHR), has today. Dynamic range > 6 decades . book Page 1 Wednesday, October 12, 2011 4:56 PMSpectraMax Plus 384 Microplate Reader (Molecular Devices cat. When the user applies a set temperature of 37°C, the top is heated to 37. Devices PathCheck® Sensor—the only patented technologySpectraMax ® M5 Multi-Mode Microplate Reader (Molecular Devices) Gemini EM Microplate Reader (Molecular Devices). Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. Method 1. The FLIPR Fluorometric Imaging Plate Reader system addresses the industry's requirements for higher throughput, minimized sample volume, and cost reduction. 384-Well Microarray/High Sample Recovery Plate. Selects either 96-well or 384-well plate for a stand-alone read. x. Published Dec 16, 2020 | Updated Nov 07, 2022. UV and visible absorbanceLocate the User Guide on your SoftMax Pro computer for version 6 and version 7. 0 mm Holex HEXAGON ballhead bolt driver to loosen the screw located inside the Transport Lock opening until you feel the spring release. It is recommended that you then centrifuge the plates at 1000 rpm for up to 4 minutes (brake off). FlexIII. Aspirating and dispensing of wash buffer can occur simultaneously in all wells via AquaMax® 4000 Microplate Washer with a 96- or 384-well head. 20 attomol ATP per well. The system comes with a single plate loading adapter and a choice of magazines for 20, 40 or 50 SBS-standard 96- and 384-well. (96- and 384-well with pipetting) 6-384. Detailed thermal cycling conditions are listed in Table 2. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. Filter. The plate was mixed gently for 2 minutes on a plate shaker and then allowed to incubate at room temperature for 10 minutes to stabilize luminescence. 6- to 1536-well plates Exceeds. All measurements were performed in six replicates and cell toxicity was calculated as the percentage of the OD value of untreated or treated. With the FLIPR 384 , you get the sensitivity, data fidelity, and real-time, kinetic information of the FLIPR I system in a 384-well mode. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. With optimized reagents and the industry-leading data acquisition and analysis tool, SoftMax Pro® 7 Software, the SpectraMax® iD3. Molecular Devices deliver high throughput while showing good correlation with manual patch clamping data. 19 H mm that meet microplate industry standards. ,LTD (CAT#: STEM-S. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. 8 mm distance between well bottoms to plate bottom; 50μL total well volume, with recommended working volume of 5-40μL; High base plate design is compatible with automation and for bar coding; Validated by Molecular Devices for the FLIPR reader. 0. The plate reader can measure multiple readouts, including UV and. Fastest Read Time - 96-well plate: 20 sec; 384-well plate: 30 sec. For more sample throughput, the system can6- to 1536-well plates 4 96- to 384-well plates 4 With up to five modes of detection, F3/F5 Multi-Mode Microplate Readers support a wide variety of applications in life science research. 2. 00. Select Start>Control panel>Device Manager. Supplier: Molecular Devices. Contains a revised proprietary masking dye with higher light extinction in the extracellular solution to significantly reduce background and increase signal window. Catalog number: AB1384W. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. 5 ml microcentrifuge tubes 35 mm Petri dishes 12 mm × 50 mm test tubes (optional). #2704174, 2705402, 2705412, 2704180; Drummond Digital Microdispenser cat. Nanoracks’ Plate-Reader-2 (2nd generation) is a reconfigured Molecular Devices SpectraMax M5e – one of the most reliable, durable, feature-rich microplate readers on the market. 8 mm distance between well bottoms to plate bottomValidated by Molecular Devices for the FLIPR reader. The estimated lower limit of detection (LLD) in both 96- and 384-well plates is < 2 fg/well for firefly luciferase in the LMax II 384 and Analyst GT and 2–3 fg/ well in the SpectraMax M5. 0112-0127C 9 Chapter1:Introduction TheFlexStation® 3Multi-ModeMicroplateReadercombinestheperformanceofadual-monochromator,multi-modemicroplatereaderandanintegrated8. SOP Title: Use and Maintenance of a Molecular Devices M5 Plate Reader Document ID: HSL_EQ_005 Version 2. The guidelines for cuvette use in SpectraMax instruments are the same as those that apply to any high-quality spectrophotometer. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. Select the Driver tab. EMax. 384 well polystyrene microplates have plate dimensions of 127. 2. Higher density microplates (384- or 1536-well microplates) are typically used for screening applications, when throughput (number of samples per day processed) and assay cost per sample become critical parameters, with. 100 fmol 1536-well (8 µL) 0. Fluorescence Microplate Reader Comparison Chart. The VICTOR Nivo. Each kit is sufficient. 2. 0 out of 5 $ 8,495. Tb. In addition, the iD5 reader measures TRF and FP and. 9. However, for greater flexibility, some instruments can accommodate 6- to 1536-well plate formats. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. Assay setup for a 384-well low-volume plate. Calcium flux was measured with a FlexStation 3 Microplate Reader using the Flex (fast kinetic) read type. x. x. Source plate capacity; 1 x plates. “We continue to expand on our high-quality line of microplate reader platforms with a new line of absorbance microplate readers”, said Greg Milosevich, President of Molecular Devices. Important things to consider when purchasing a multimode microplate reader. Minimum volume and maximum throughput with 96- or. The default pipettor dispensing speed is 50 µL/sec for 96-well plates and 20 µL/ sec for 384-well plates. This is equivalent to having 511 built-in filters, 384-well: 0. Streamline your workflow with comparative confluence assays to identify and verify gene edits. The ImageXpress® Pico Automated Cell Imaging System is more than a digital microscope, combining high-resolution imaging with powerful analysis. Monitor reader performance on demand to ensure data quality is not compromised between PM/OQ. M5. MultiWash™+ Microplate Washer benefits include, walk-up usability, 4 wash and rinse. the Gemini XPS reader. x. Related products. All standard 96- and 384-well microplates, strip wells, and filter-bottom micro-plates can be used in the SPECTRAmax PLUS 384. Microplate readers are commonly used in life science laboratories. With SoftMax Pro Software, the PathCheck Sensor automatically normalizes the well absorbance. The Embla 96/384 Well Washer accepts 96-and 384-well format microplates and is ideal. Microplate Formats: 6, 12, 24, 48, 96, 384. Published Dec 16, 2020 | Updated Dec 16, 2020. is a welcome addition to any lab that is routinely measuring concentration or absorbance in 96 and/or 384 well plates. ©2017 Molecular Devices, LLC 3/17 0120-1441I Printed in USA Figure 3. Shaking: Linear, orbital, and double orbital. For the FlexStation 3 Reader - Keep the Black Plate Adapter in place fro both Top and Bottom reads. SpectraMax® Plus 384 Microplate Reader (Molecular Devices cat. A microplate reader that can detect two or more applications is considered a multi-mode plate reader. 2. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and Bottom read. Danaher Inc 384 well plate 384 Well Plate, supplied by Danaher Inc, used in various techniques. Find our technical support information along with contact details. Signals are detected at two different wavelengths (typically 620 nm and 665 nm), which are used to calculate the. ‘StimB’ is Stimulation Buffer, included in the IP-One Gq kit. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. Outer wells aligned for proper viewing with FLIPR Ideal. 96-384. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. x. or use the modified protocol below for the generation of NPCs (see Note 1). Efficiency. Features of Streptavidin Coated Plates include: • Approximate binding capacity is ∼5 pmol biotin/well. SpectraMax M Series Multi-Mode Microplate Readers Molecular Devices LLC Applications: Absorbance, Cell Health, Cell Viability, Cellular. 20 attomol ATP per well. com Check our website for a current listing of worldwide distributors. In simplest terms, a plate reader measures and. x. Microplate is validated by molecular devices for the FLIPR reader. Afterwards, 25 μL SpectraMax Glo Steady-Luc working solution was added to the wells containing luciferase and controls. Validated by Molecular Devices for the FLIPR reader. 2. 384-well SBS microplates are designed with corners cut at a1 and h1 positions to conform to SBS nomenclature. 20 plates/hour (2-minute read time) 96-well 1,920 data points/hour 384-well 7,680 data points/hour 1536-well 30,720 data points/hour Bar code manual mode Keyboard entry Bar code remote mode Short or long side Temperature control Ambient +5°C to 40°C General specifications Dimensions (in. All stand-alone instrument functions can be controlled using the software. flat meniscus), but is approx 15 mL. 96-, 384-, and 1536-well microplates. Molecular Devices has provided scientists with tools to expand the boundaries of their research. Our washers provide speed and configurability options—from single-tube dispensing to washing full 96- and 384-well plates. Reconstitution of reagents. 76 ± 0. ©2017 Molecular Devices, LLC 3/17 0120-1441I Printed in USA Figure 3. We would like to show you a description here but the site won’t allow us. . All stand-alone instrument functions can be controlled using the software. SLS & DLS: 2 µL quartz cuvettes 45 µL quartz cuvettes 4 mL generic glass cuvette DLS only:Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. The MultiWash+™ Microplate Washer is an automated, compact, quiet, efficient washer with 20 different wash protocol options. A: adipocytes; B: fibroblasts; C: no cells (uptake reagent only). The SpectraMax® L Microplate Reader measures flash and glow luminescence assays in both 96- and 384-well plates. Determine concentration using the Beer-Lambert LawMolecular Devices’ FilterMax™ F5 Multi-Mode Microplate Reader was tested for compatibility with Life. Ensure data accuracy of your reader. Extended linear dynamic range. x. Published Dec 16, 2020 | Updated Dec 16, 2020. x. )Step 4: Incubate at room temperature for 1 hour, protected from light. formats from 6- to 384-wells, the SpectraMax iD3 reader is the complete solution for all your research needs. All microplate washers enable users to program tank selection, volumes, step times, and cycles for customized procedures. FLIPR Calcium 4 Assay Kit (Molecular Devices, San Jose, CA, USA). SpectraMax ID5 Plate Reader (Molecular Devices). The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. Figure 3. 0nm increments. The. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. • Tyrosine Kinase Plate Please contact your Molecular Devices sales representative. 1536-well plates < 100 amol (384-well) 1 HTRF • Cisbio HTRF detection with optimized Xenon light source and . Video Description: The video below gives an overview of the Molecular Devices SpectraMax M2 Multi-Mode Microplate Reader, and also demonstrates its functionality. The purpose of this procedure is to set instructions in the proper use and handling of the Molecular Devices M5 Plate Reader. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. 190. The color touch screen provides a visual user interface, making programming fast and intuitive. For SpectraMax L or LMax II, LMax II 384 - no adapter used. Note: These settings are based on necessary cookies. 2. M2. 4 Equipment. Description: The SpectraMax® L microplate reader measures flash and glow luminescence assays in both 96- and 384-well plates. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. Two high-energy xenon flash lamps: Reading capabilities. The instruments offer 96- and 384-well microplate-to-microplate fluid transfer (8 or 16 wells at a time), and can read microplates having 6, 12, 24, 48, 96, and 384-wellThe FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. 96-, 384-, and 1536. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. Fluorescence Microplate Reader Comparison Chart. Abs). Top. explore more. All stand-alone instrument functions can be controlled using the software. With the QuickSync client installed on your computer, your SpectraMax iD3 reader can push data to any computer within the same network. 0 mP 96-well. They are also fully compatible with the FlexStation 3 Multi-Mode Microplate Reader. After incubation of the cells with compounds, add 100 µL (for 96-well plates) or 25 µL (for 384-well plates) of Dye Solution per test well. VIS absorbance detection. smartinject technology, atp a, spectramax i3x multi-mode microplate reader, luminescent cell vi, spectramax i3x multi mode microplate reader, spectramax i3x. 384 Well Plates; Wavelength(s): 200 to 1000 nm (Abs), 250 - 850 nm (Fluor) Specifications/Features: Shaking, Temperature control, Cuvette port; Read More. Learn more about SpectraMax Plus 384 Microplate Reader >>Rating: 5. High-throughput screening (HTS) can efficiently assay multiple discrete biological reactions using multi-well microplates. 1. To maintain confidence in the standards, Molecular Devices recommends having validation plates recertified at one-to Molecular Devices for recertification at our ISO 17025 accredited lab are disassembled, cleaned, calibrated, andSpectraMax® iD5 Multi-Mode Microplate Readers,6 to 384-Well Microplates, Molecular Devices, LLC (CAT#: STEM-LE-0504-LC) Product Keyword. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. SpectraMax iD3 reader with touchscreen and inserted USB flash drive. Contact; Bioz Stars; Bioz vStars; 86 : Buy from Supplier : Structured Review. Detection cartridge modularity allows for easy addition of new read modes within minutes without. X. These advertising cookies will no longer be set for this browser and device. Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. The user must ensure that the meniscus is comfortably above the light beam in standard cuvettes and that the sample chamber in a microcuvette is aligned properly with the beam. That explains the lower values on the LmaxII384 plate reader. Plate readers avoiding cross-talk are recommended for luminescence measurement in 384 well plates. A snapshot of the Settings screen is shown in Figure 2. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Learn how the PathCheck feature can be applied to protein quantitation experiments using Molecular Devices absorbance-based microplate readers. 96/384-well plate formats. 9. Get Quote . 96-Deep Round or Square Well Plates. All stand-alone instrument functions can be controlled using the software. Ensure your assay quality with quality tips Certified RNase-/DNase-free Nonpyrogenic Nonsterile 50 racks/case. Analyst, M5, Flex 3, and SpectraMax L readers work differently. Plate stacker and robot integration The SpectraMax M2 and M2e readers can be integrated with the StakMax® Microplate Stacker from Molecular Devices in a matter of minutes. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. The systems can handle any slide-based microarray study, from small one- or two-fluor applications to multiple-fluor high-throughput projects requiring automated. Flexibility to read a variety of plate formats - SpectraMax® Absorbance Microplate Readers can run both cuvette-based and microplate reader applications on the same instrument.